Recommendations for ICD assessment after Mustard and Senning operations, adapted from the 2018 EHRA position paper.

Scope and evidence

Patients who have had a Mustard or Senning operation are at risk of ventricular arrhythmias and sudden death. Risk stratification for primary-prevention ICD implantation is not well established. New Zealand experience has found appropriate shocks very infrequent in this primary-prevention population.

These recommendations are modified from the 2018 EHRA position paper. Its scientific rationale differs in some respects from most society guidelines; consult the full paper for that explanation.

Hernandez-Madrid A et al. Arrhythmias in congenital heart disease: a position paper of EHRA, AEPC and the ESC Working Group on Grown-up Congenital Heart Disease, endorsed by HRS, PACES, APHRS and SOLAECE. Europace 2018;20:1719–1753.

Secondary prevention

ICD is recommended for patients who are survivors of an aborted cardiac arrest due to VF or haemodynamically unstable VT after evaluation to define the cause of the event and exclusion of any reversible causes (EHRA consensus statement: recommended/indicated)

Sustained VT

ICD is recommended for patients with symptomatic sustained VT who have undergone haemodynamic and electrophysiological evaluation (EHRA consensus statement: recommended / indicated)

Syncope of unknown origin

ICD implantation should be considered in patients with syncope of unknown origin in the presence of either advanced ventricular dysfunction or inducible sustained VT or VF on ventricular programmed stimulation (EHRA consensus statement: may be used or recommended)

Advanced systemic RV dysfunction

ICD therapy may be considered in patients with advanced systemic RV dysfunction in the presence of risk factors such as non-sustained VT, NYHA Class II or III, QRS duration ≥140 ms or severe systemic AV valve regurgitation (EHRA consensus statement: may be used or recommended)

ICD Contraindications

ICD is contraindicated in patients with CHD with life expectancy with an acceptable functional status ≤1 year, incessant VT or VF, significant psychiatric illness that may be aggravated by ICD implantation or preclude systematic follow-up, and patients with drug-refractory NYHA Class IV symptoms who are not candidates for cardiac transplantation or cardiac resynchronization therapy (EHRA consensus statement: Should NOT be used or recommended)